SG-SOP-014
REV 0
PUMP P-101
SAMPLE
Isolate and lock out centrifugal pump P-101
- 1. Confirm the pump is the right asset. Tag matches P-101.
- 2. Stop the pump. Watch the impeller coast down.
- 3. Open the isolator and apply the lock. Keep the key.
- 4. Close suction and discharge. Open the bleed.
- 5. Prove the gauge reads 0 kPa before you break a joint.
Hold / Caution
Do not remove the lock. Do not open a flange while the gauge is above 0 kPa.